INVERTER LS100A MODE
 
Innovatory unique outstanding and perfect
Space vector design:
  Space vector voltage modulation
Silent design:
  IGBT module, high carrier frequency
Smooth current:
  Similariry Sin wave, to ensure motor smoothly rotation, safety and no
  vibration
Safety design:
  Reduce noise, restrain emission
Multiple selection:
  Available to drive motor with different four power capacity
Low price level:
  Low price level to be competitire
 
Standard Specifications
Voltage
200V Single Phase
Model

LS100A-204K

Output

MAX Motor(KW)
60W
100W
150W
150W

Rated Output AMP.

0.42

0.7

0.9

1.2

MAX. Output Voltage

200V ~ 240V Three phase matched voltage
Highest Output Frequency Up to 120Hz by Analog setting
Power Source Rated Voltage & Frequency Single Phase 200/208/220 50Hz 200/208/220/240V 60Hz
Allow Voltage Variance  10%
Control System
Control Principle SV PWM sine wave, voltage space vector control
Range of Frequency Control 1 ~ 120Hz
Frequency Precision Analog Command: 0.1% (25oC 10oC)
Motor capacity Adjust Dip-Switch to be capable drive multiple motor capacity including of 60W, 100W, 150W, 200W

Frequency Resolution

Analog, 0.1Hz

Output FRE. Resolution

0.1Hz

Overload Capability

Rated Output AMP.150%, 60sec.

Speed Reference DC 0 ~ 5V

Acc/Dec Ramp

0.1 ~ 120sec

Torque of Braking

About 20%

Protection Function

V/F Curve

Torque compensation by any V/F curve setting

Instantaneous Over Current

Trop on upon 200% rated current

Overload Capacity

150% rated current in 60 sec.

Over-Voltage or Low-Voltage

DC Bus voltage higher than 400V or lower than 200V will have the drive trip

Instantaneous Power Loss

Trip with in 15m/sec

Charging Indication

DC Bus voltage higner than 50V the charging lamp is on light

Rotation System

Input

Rotation

FWD & REV rotation or individual command

Reset

Reset automatically or by terminal

Multi-Function Input

Second speed control via terminal point

Output

Analog Voltage

Analog Voltage Output DC 0 ~ 5V (internal)

Display

Status LED Display

Abnormal function display for Run/Stop yellow: power on . Red: fault motion Green: starting run

Environment

Location

In door, no corrosive gas or liquid and free from dust

Ambient Temp.

10oC ~ 40oC

Storage Temp.

-15oC ~ 40oC avoiding high temperature to damage capacitor

Humidity

Below 90% RH, non-condensing

Vibration

Below 0.5G

BRAKING UNIT LSBR MODE