INVERTER LS200A MODE
 
Innovatory unique outstanding and perfect
Space vector design:
  Space vector voltage module with unique style
Silent design:
  IGBT module, high load wave, high speed switching with silent
Smooth current:
  Trending Sin wave, motor smooth rotation without vibration and safety
Safety design:
  Reducing confused/mixed message transference and restraining
  transmission and radiant wave
Bright appearance:
  Aluminum made outer shell, with light and efficient measurement and
  excellent cooling capacity, strong and durable
Low price level:
  It is competitive for low price level market with good potential for
  transmission equipment


LS200A Inverter
Speed Meter
Potentiometer


Red locus
Curve of normal current output

Yellow locus
Curve of general v/f controlled current output.

Blue locus
Compensated curve of voltage space vector control.

 

Standard Specifications
Voltage 200V(Single)
Model

LS200A-20-5

LS200A-2001S

LS200A-2002S

MAX Motor(KW)

0.4

0.75

1.5

Control Characteristics

Rated Output Capacity

1.2

1.7

2.8

Rated Output AMP.

3

4.5

7.5

MAX. Output Voltage

200V~240V Three phase matched voltage

Power Source

Highest Output Frequency Up to 120Hz by Analog setting
Rated Voltage Variance 200/208/220/240V 60Hz
Allow Voltage Variance 10%
Control System Control Principle SV PWM sine wave, voltage space vector control
Range of Frequency Control 1~120Hz
Frequency Precision Analog Command:0.1%(25oC 10oC)

Frequency Resolution

Analog operator:0.1Hz

Output FRE. Resolution

0.1Hz

Overload Limited

Rated Output AMP.150%, 60Sec.

Signal of Frequency Setting

DC 0~5V

Time for Speed Acc/Dec.

Individual Setting Second speed setting acc/dec in the meantime

Torque for Braking

About 20%

V/F Curve

Automatic torque compensation or compensation by any V/F curve setting.

Protection Function

Instantaneous Over Current

Output stop for 200% rated current

Overload

Above 150% rated current, output stopped in 60 sec.

Over-Voltage or Low-Voltage

Main & return DC lines voltage above 400V or under AC 200V 1 phase 170V)output stopped

Instantaneous Power Break

Stop over 15ms

Ventilation Over-Heat

Protected by thermo-switch

Charging Indication

Main & return DC lines voltage above 50V,charging lamp is on light

Rotation System

Input

Rotation

FWD & REV rotation or individual command

Recovery

Upon removal of protection action signal

Multi-Function Input

Second speed control via terminal point

Output

Analog Voltage

Analog Voltage Output DC 0~5V

Abnormal Contact

Abnormal output contact(addendum function)

Display

Abnormal LED Display

Abnormal function display for Run/Stop yellow: power on . Red: fault motion Green: starting run

Environment

Location

In door, no corrosive gas or liquid and free from dust

Ambient Temperature

10~+40oC(not frozen)

Storage Temp.

-15oC~40oC(avoiding high temperature to damage capacitor in main line)

Humidity

Below dew point, up to 90%RH

Vibration

Below0.5G

 
Main Circuit Wiring
 
Terminal Wiring Meyhod

BRAKING UNIT LSBR MODE

INVERTER LS200A MODE